Soil Testing Lab in Bengaluru — Geotechnical Analysis

NABL accredited geotechnical soil testing per IS 2720 at our lab on Bagalur Main Road, Yelahanka, Bengaluru. CBR, Proctor, field density, and classification tests.

Geotechnical Soil Testing for Bengaluru Construction

Bengaluru's varied soil conditions — from red laterite to black cotton soil — demand thorough geotechnical investigation before construction. V2 Civil Diagnostics performs a full range of soil tests including CBR, standard and modified Proctor compaction, Atterberg limits, and field density measurements. Our results guide foundation design, road subgrade evaluation, and earthwork specifications. All tests follow IS 2720 methods under NABL accredited, ISO/IEC 17025:2017 certified protocols. We serve residential, commercial, and infrastructure projects across Bengaluru and North Karnataka.

Soil Tests We Perform

Our comprehensive testing covers all essential parameters required by Indian Standards and NABL protocols.

Soil – Mechanical Tests

TestIS CodeAccreditation
Water ContentIS 2720 Part 2NABL
Specific GravityIS 2720 Part 3Non-NABL
Sieve Analysis (Grain Size Distribution)IS 2720 Part 4NABL
Liquid Limit / Plastic LimitIS 2720 Part 5NABL
Light Compaction (MDD & OMC)IS 2720 Part 7NABL
Heavy Compaction (MDD & OMC)IS 2720 Part 8NABL
CBR – California Bearing RatioIS 2720 Part 16NABL
FSI – Free Swell IndexIS 2720 Part 40Non-NABL
Dry Density by Sand Replacement (Oven Dry Method)IS 2720 Part 28Non-NABL
Dry Density by Core Cutter MethodIS 2720 Part 29Non-NABL

Soil – Chemical Tests NABL

TestIS CodeAccreditation
Organic MatterIS 2720 Part 22NABL
SulphateIS 2720 Part 27NABL
pHIS 2720 Part 26NABL

GSB (Granular Subbase) / WMM (Wet Mix Macadam) – Mechanical Tests Non-NABL

TestIS CodeAccreditation
Water ContentIS 2720 Part 2Non-NABL
Sieve AnalysisIS 2386 Part 1Non-NABL
Liquid Limit / Plastic LimitIS 2720 Part 5Non-NABL
Heavy Compaction (MDD & OMC)IS 2720 Part 8Non-NABL
CBR – California Bearing RatioIS 2720 Part 16Non-NABL
Elongation IndexIS 2386 Part 1Non-NABL
Flakiness IndexIS 2386 Part 1Non-NABL
Water AbsorptionIS 2386 Part 3Non-NABL
Crushing ValueIS 2386 Part 4Non-NABL
Aggregate Impact ValueIS 2386 Part 4Non-NABL
Aggregate Wet Impact ValueIS 5640Non-NABL
SoundnessIS 2386 Part 5Non-NABL
Mix Design – GSB & WMMMoRTHNon-NABL
Dry Density by Sand Replacement (Oven Dry Method)IS 2720 Part 28Non-NABL

GSB / WMM – Chemical Tests Non-NABL

TestIS CodeAccreditation
Soundness – By Magnesium SulphateIS 2386 Part 5Non-NABL
Soundness – By Sodium SulphateIS 2386 Part 5Non-NABL

Frequently Asked Questions — Soil Testing

V2 Civil Diagnostics is a NABL accredited soil testing lab on Bagalur Main Road, Yelahanka, Bengaluru. We serve projects across the city, including Yelahanka, Devanahalli, Jakkur, and North Bengaluru.

California Bearing Ratio (CBR) measures the strength of subgrade soil. It is essential for road pavement design and is required by NHAI, KPWD, and BBMP for road construction projects in Bengaluru.

Yes. Our team visits your site in Bengaluru for field density testing using the core cutter method per IS 2720 Part 29. This is commonly required during earthwork compaction checks.

Bengaluru's geology includes red laterite soil, red sandy soil, and pockets of black cotton (expansive) soil in some areas. Our soil classification tests (sieve analysis, Atterberg limits, free swell index) help identify the soil type at your specific site.

For a standard suite of tests (CBR, Proctor, Atterberg limits, sieve analysis), approximately 30-50 kg of representative soil is required. Our team can guide you on proper sampling.

Most soil tests are completed within 5-7 working days. CBR (soaked) requires a 4-day soaking period as per IS 2720 Part 16 before testing, which extends the turnaround.

Ready to Get Your Soil Tested?

NABL accredited results. Fast turnaround. Full regulatory acceptance.

REQUEST A QUOTE
Call Get Quote Directions